  • Maintenance and Servicing of AGISEAL Electrosurgical Generator SL100M
    Sep 22, 2025
    With the evolution of modern surgical treatment concepts, the number of OR medical devices continues to increase. The function and performance of these devices directly impact surgeons' operational proficiency and condition, ultimately affecting surgical outcomes. Therefore, ensuring optimal device performance during use is crucial. Here, we outline key maintenance and servicing points for the ShouLiang-med advanced electrosurgical vessel sealer dividers system SL100M.     How to Properly Install and Maintain the SL100M?   Installation:   First, inspect the high-frequency surgical generator and accessories to ensure they are complete and undamaged. Do not use any damaged devices.   Secure the high-frequency surgical equipment to a stable surface, such as a table, platform, or cart.   When placing the unit, ensure at least 10 cm to 15 cm of clearance is maintained above, on the sides, and behind the unit to facilitate cooling.    Connect one end of the power line to the power socket on the rear panel of the generator, and plug the other end into a grounded power outlet. Connect the foot switch connector to the foot switch socket on the rear panel of the generator. Connect the instrument plug to the instrument socket on the front panel of the generator.    Press the power switch to turn on the generator. The green light will illuminate. Verify the following: the company logo appears on the screen, The power-on self-test process emits an audible sound.     If the self-test is successful, the main interface will be displayed, and the generator is ready for normal use.   If the self-test fails, the display will show the corresponding fault code. Please refer to the "Common Faults and Troubleshooting" section of the manual or contact an engineer.   Cleaning and Disinfection:   Thoroughly scrub all surfaces of the generator, power cord, and foot switch with a mild detergent or disinfectant solution and a soft damp cloth.The device can withstand frequent cleaning without degradation of the housing or display quality.   Warning: Risk of electric shock. Before cleaning, turn off the power supply and unplug the generator to ensure the device is isolated from the main power source.   Note: Do not use abrasive cleaning or disinfectant solutions (such as formalin), solvents, or other materials that may scratch the panel or damage the device.   Note: The instrument is not completely sealed. Liquids must not seep into the unit. Do not place liquid containers on the generator, and avoid spraying cleaning solutions directly onto it, as this may damage it.   Servicing   It is recommended that a comprehensive inspection of the generator and all accessories be conducted annually by qualified full-time personnel. Adjust the system according to technical requirements to ensure it remains in optimal condition.   It is recommended to inspect the power cord before each use of the system, or at intervals recommended by your hospital. Check the power cord for exposed wires, cracked outer casing, frayed edges, or damaged plugs. Replace any damaged cords.    Malfunction of internal components may cause the fuse to blow. If the wall outlet has power but the generator fails to complete the power-on self-test or stops working, replace the fuse of the device.   During maintenance, surface dirt such as dust and oil stains can be cleaned using the traditional method of wiping with a dry cloth.   Avoid severe vibrations, exposure to harmful gases, and liquid ingress.   Keep the surfaces clean. Refer to the cleaning methods described above.
    Read More

leave a message

leave a message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.
submit
Contact Us:info@shouliang-med.com

Home

Products

whatsApp

contact